Pressure Cells or Pressure Tanks are ideal for a wide range of general applications. As a guide, the usable amount is a third of the capacity of the tank/cell.
PRESSURE WAVE SERIES
Quick Overview
Pressure Wave diaphragm pressure tanks are ideally suited for a wide range of general applications including pump booster systems, thermal expansion, irrigation systems and to minimise water hammer.
Special Features
- Single diaphragm design 100% potable quality butyl
- Patented 316 stainless steel connection
- Virgin polypropylene liner, so no water touches plain steel
- Internal clench ring becomes more secure at higher pressures
- Appliance quality two part polyurethane, epoxy primed paint finish-almond
- Brass stemmed air valve and o-ring sealed valve cap
- NSF standard 61, CE/PED, WRAS approvals
- Pre-Charged air side 28 PSI/ 1.9 Bar
- Maximum temperature up to 90 °C
- Standard maximum pressure 150 PSI/ 10 Bar
- Models available up to 235 PSI/ 16 Bar
- 5 Year Replacement Warranty
Product ID | Description | Price |
---|---|---|
FLE-AWB18V | 18 Litre Vertical, 10 Bar 1" MBSP | 0.00 |
FLE-AWB24V | 24 Litre Vertical, 10 Bar 1" MBSP | 0.00 |
FLE-PWB2V | 2 Litre Vertical, 10 Bar 1" MBSP | 0.00 |
FLE-PWB8V | 8 Litre Vertical, 10 Bar 1" MBSP | 0.00 |
FLE-PWB35V | 35 Litre Vertical, 10 Bar 1" MBSP | 0.00 |
FLE-PWB60V | 60 Litre Vertical, 10 Bar 1" MBSP | 0.00 |
FLE-PWB80V | 80 Litre Vertical, 10 Bar 1" MBSP | 0.00 |
FLE-PWB100V | 100 Litre Vertical, 10 Bar 1" MBSP | 0.00 |
FLE-PWB150V | 150 Litre Vertical, 10 Bar 1" MBSP | 0.00 |
FLE-PWS20H | 20 Litre Horizontal, 10 Bar 1" MBSP | 0.00 |
FLE-PWS60H | 60 Litre Horizontal, 10 Bar 1" MBSP | 0.00 |
FLE-PWB8V-16 | 8 Litre Vertical, 16 Bar 1" MBSP | 0.00 |
FLE-PWB18V-16 | 18 Litre Vertical, 16 Bar 1" MBSP | 0.00 |
FLE-PWB80V-16 | 80 Litre Vertical, 16 Bar 1" MBSP | 0.00 |
FLE-PWB8V-25 | 8 Litre Vertical, 25 Bar 1" MBSP | 0.00 |
FLE-PWB24V-25 | 24 Litre Vertical, 25 Bar 1" MBSP | 0.00 |
FLE-PWB100V-25 | 100 Litre Vertical, 25 Bar 1" MBSP | 0.00 |
CHALLENGER SERIES
Quick Overview
Challenger diaphragm pressure tanks are ideally suited for a wide range of general applications including; pump booster systems, thermal expansion, irrigation systems and to minimise water hammer.
Special Features
- Patented Controlled Action Diaphragm CAD Design, 100% portable quality butyl
- Patented 316 stainless steel elbow connection
- Connection includes a diffuser to suspend any solids and prevent clogging
- Internal clench ring becomes even more positive at high pressure
- Double diaphragm reduces condensation due to “air buffer” design
- Appliance quality two part polyurethane, eproxy primed painted finish, almond
- Brass stemmed air valve and o-ring sealed valve cap
- NSF standard 61, CE/PED, WRAS approvals
- Pre-charged air side 38 PSI/ 2.6 Bar
- Maximum temperature up to 90°C
- Standard maximum pressure 150 PSI/ 10 Bar
- 5 Year Replacement Warranty
Product ID | Description | Price |
---|---|---|
FLE-C200V | 200 Litre Vertical, 10 Bar 1-1/4 inch | 0.00 |
FLE-C240V | 240 Litre Vertical, 10 Bar 1-1/4 inch | 0.00 |
FLE-C310V | 310 Litre Vertical, 10 Bar 1-1/4 inch | 0.00 |
FLE-C450V | 450 Litre Vertical, 10 Bar 1-1/4 inch | 0.00 |
Tank Pre-charge Instructions
- Turn the power and water supply off, then open a tap to drain the tank before adjusting pre-charge.
- For a pressure switch controlled pump with a differential set up to 20 psi (1.4 bar), the pre-charge should be set to 2 psi (0.2 bar) below the cut-in pressure.
- For a pump controlled by a pressure switch with a pressure differential greater than 20 psi (1.4 bar), electronic controls should be set to 65% of cut-out or max system pressure.
- For hot water expannsion applications, the tank pre-charge should be set equal to the system fill pressure or the main pressure.